5.
Command Center Warning Signals
4.
The Command Center contains a built-in sounder used as an
interior warning device. A bell or siren can also be mounted on
the exterior of your premises to alert your neighbors of an
emergency, and to give the police an audible reference to help
them locate the alarm. Several different warning signals are
emitted from the Command Center to alert you when an event
occurs (not all signals will be heard outside). Some of these tones
are optional, and can be selected by your alarm technician.
1.
Entrance Warning: The Command Center beeps during
the entry delay period to remind you to disarm your security
system. If the security system is not disarmed before the
entry delay expires, an alarm signal may be sent to the
Central Station and the alarm audible sounds.
2.
Keystroke Entry: Pressing any key on the Command
Center sounds a short beep tone, indicating that the entry is
accepted.
3. Faulted Zone: The Command Center sounder is activated
for two seconds after you enter an arming command to 6.
indicate that a zone is faulted, and the indicator of the faulted
zone lights.
Watch Tone: When the Perimeter Watch Mode is
activated, the Command Center emits a brief tone to alert
you when any perimeter zone is faulted and the zone indicator
lights to indicate which zone is faulted. The tone sounds
only when the door or window is opened. It does not sound
again for that zone until the door or window is closed and
then reopened.
Service Tone: Some zones may be programmed to sound
a service tone when they are faulted. The zone indicator light
annunciates which zone is faulted. To silence the service
tone, emer COMMAND 4 or enter your personal passcode.
plus
ENT
j, at the Command Center.
NOTE: Some zones, such as fire zones, may be
programmed so that the sounder cannot be silenced until the
zone fault is corrected.
□ My system can be silenced by entering COMMAND 4
or by using my personal passcode plus
iii
O My system cannot be silenced unless the zone is
returned to normal.
Telephone Trouble: If the security system cannot report
to the Central Station due to telephone line trouble or other
cause, the Commnad Center emits a steady beep tone. This
tone may be silenced by entering COMMAND 4 or your
personal passcode plus |
ENT
Arm Your Entire System
with Delays
O I have this feature.
O I do not have this feature.
COMMAND 1 is used to arm the entire system, both perimeter
and interior zones. Once you have entered COMMAND 1, the
exit delay time starts. You now have a predetermined amount of
time to exit the protected area before the system arms. During the
exit period, you can move through motion detectors or any
protected area on your way to any exit without causing an alarm.
To cancel COMMAND 1, enter your personal passcode and press
ENT
NOTE: If you leave the building after the exit time expires, you
may begin the entry delay, or initiate an alarm. If this happens,
disarm your system by entering your personal passcode and press
ENT
. If your system reports to a Central Station, you may
need to call them if an alarm occurs.
COMMAND
Application
COMMAND 1 is useful in applications where you want your
cleaning service, a serviceperson, or anyone else to arm your
system when they leave, but you do not want them to have the
passcode to disarm the system. COMMAND 1 arms the system,
but it will not disarm the system.
Arming with COMMAND 1:
1. Ensure that all zones are secure. All of the Zone Status
indicator lights on the Command Center should be off.
2.
Press the rCOMMAND
I
bar. The Command Mode
3.
4.
indicator light comes on.
Press the 11 |key. The PERIMETER indicator and the
INTERIOR indicator lights begin to flash on and off. This
indicates that the system has begun exit delay time.
To disarm your security system or cancel COMMAND 1,
enter your personal passcode and press
ENT
before the
delay time expires.