OPTIONS PROGRAMMING
NOTES: (1) Options #2, #4 and #5 DO NOT APPLY TO THE EZ-10 MODEL (NO KEYLESS ENTRY)
(2) For EZ-10 Model, tap the Brake Pedal to select/toggle the option values.
* = Default Value
Option
#
Option Description
Option Values
Button #1
LOCK
Button #2
UNLOCK
1.
Tach or Tachless Mode
Tach = Engine RPM
Tachless = Voltage monitor
Tach
Tachless*
2.
Autolock with RPM/Ignition
ON or OFF
ON
*OFF
3.
OEM Disarm/Unlock Pulse
0.75 sec. Normal or 0.5 Shorter
Short
*Normal
4.
Double Unlock Pulse
Single or Double Unlock Pulse
Double
*Single
5.
Lock During and After
Remote Start Abort
ON or OFF
OFF
*ON
6.
Diesel Glow Plug Delay
Lock button = 10 Sec.
Unlock button = Gas 3 sec
Delay
Tap Brake 3X = 20 Sec.
Start Button = 30 Sec.
10 Sec.
*Normal
(3 sec. delay)
7.
Remote Start Engine Run
Time
Lock Button = 12 Min.
Unlock Button = 24 Min.
Tap Brake Pedal 3X = 36 Min.
Start Button = 48 Min.
12 Min.
*24 Min.
8.
Option reset
Unlock Button
Reset to
Default
OPTION DESCRIPTIONS:
1. Tach or Tachless Mode:
This option sets how the unit monitors your engine. You can program either for Tach mode in which the unit uses a
Tach signal (RPM) or for Tachless mode that monitors voltage level. See pages 11-12 for more information and
additional steps for actual Tach learning and Tach finder modes. The system will only learn Tach when the engine is
running and the tach wire is connected to an A/C tach source.
14