beautypg.com

Vermont Casting P User Manual

Page 4

background image

4

20007967

Connection to Gas Supply

NOTE: For Natural and Propane gas, you must have a manual
shutoff at the fireplace.
1. Place the burner pan in the fireplace. Pull the grate so the back
side of the hearth brick pulls up (1, Fig. 1) enough for you to tilt the
grate up (2, Fig. 1) to slide the pan underneath. (3, Fig. 1) The burn-
er should be located several inches from the backwall, centered left
to right.
NOTE: This is for burner connection purposes only. Exact burner
placement will be covered on Page 7, after all connections have
been made.
3. Attach the Gas Supply Fitting onto your fireplace’s gas supply
pipe, as shown in Figure 2.

CAUTION: If you answered “NO” to any item, or have any questions regarding your installation, please con-
tact your dealer/distributor for assistance.

8” adjustable crescent wrench; Pipe thread sealant compound or teflon tape; 12” pipe wrench or channel lock pliers.

Tools Required

Gas Log

Minimum Firebox Dimensions

Minimum

Gas Supply

Set

Input

Width

Flue

Pressure

Size

Btu/hr

Back

Front

Depth Height

Size

Minimum

Maximum

24”

90,000

27”

36”

18”

18”

51 sq.in.

3.5” w.c.

7.0” w.c.

Minimum Clearances & Specifications

Natural Gas Units

Propane Gas Units

Gas Log

Minimum Firebox Dimensions

Minimum

Gas Supply

Set

Input

Width

Flue

Pressure

Size

Btu/hr

Back

Front

Depth Height

Size

Minimum

Maximum

24”

50,000

27”

36”

18”

18”

51 sq.in.

11.0” w.c.

14.0” w.c.

Pre-Installation Checklist

Yes

No

Is the gas type you are using the same as the gas type listed on the rating plate for this
appliance?

Does the firebox meet the minimum size dimensions below?

Is the gas supply inlet pressure correct? Refer to Table below.

Is your fireplace plumbed with gas on the right side (facing) of the fireplace? If not,
refer to page 5.

Is the gas supply line sized properly (Minimum 1/2” Iron pipe)?

Do you have a solid fuel (wood burning) fireplace with a vented flue?

Do you have a manual gas supply valve installed at your fireplace? If not, a licensed
plumber, gas company technician or other qualified installer must install one:

Have you checked local building codes? (Check with your local building department)

Does your fireplace have a wire mesh screen in place?