beautypg.com

Table a-1 – Cisco 2900 SERIES XL User Manual

Page 84

background image

Appendix A Technical Specifications

A-2

Catalyst 2900 Series XL Hardware Installation Guide

78-6461-03

Table A-1

Technical Specifications for the Catalyst 2912 XL and Catalyst 2912MF XL Switches

Catalyst 2912 XL

Catalyst 2912MF XL

Environmental Ranges

Operating temperature

32 to 113°F (0 to 45°C)

32 to 113°F (0 to 45°C)

Storage temperature

–4 to 149°F (–10 to 65°C)

–4 to 149°F (–10 to 65°C)

Operating humidity

10 to 85% (noncondensing)

10 to 85% (noncondensing)

Operating altitude

Up to 10,000 ft (3000 m)

Up to 10,000 ft (3000 m)

Storage altitude

Up to 15,000 ft (4570m)

Up to 15,000 ft (4570 m)

Power Requirements

AC input voltage

100 to 127/200 to 240 VAC
(autoranging) 50 to 60 Hz

100 to 127/200 to 240 VAC
(autoranging) 50 to 60 Hz

DC input voltages

+5V

@9A,

+

12V

@0.5A

+5V

@12A,

+

12V

@0.75A

+5V

@22A,

+

12V

@0.75A

with two modules installed

Power consumption

70W (maximum)

239 Btus per hour

90W (maximum)
307 Btus per hour

170W with two modules installed
580 Btus per hour

Physical Dimensions

Weight

7 lb (3.2 kg)

14 lb (6.3 kg)

15.5 lb (7.1 kg) with two modules
installed

Dimensions (H x W x D)

1.73 x 17.5 x 9.79 in.
(4.4 x 44.5 x 24.8 cm)

3.46 x 17.5 x 12 in.
(8.8 x 44.5 x 30.5 cm)