Programming, Time of day, Time of regeneration – Culligan Medallist Plus Series User Manual
Page 7
Programming
7
The timer uses four buttons:
Button
Description
Set-up / Enter Key (Status)
Advance timer through display options
Regeneration Key (REGEN)
Initiate a regeneration
Toggle Down Key (“-”)
Decrease the setting
Toggle Up Key (“+”)
Increase the setting
Time of Day
This setting is used to program the current time
of day. When in this step the display will first
show “tod” for two seconds.
After “tod” is displayed, “12:00 PM” will display
(or the current set time if already programmed)
and the minutes will flash.
• The minutes are adjusted with the
“+” or “-” key until the correct value is
displayed.
• Press the “Regen” key to flash the
hours. Adjust with the “+” or “-” key
until the correct time is displayed.
Pressing the “Status” key will move to the next
programming step. Pressing “Regen” will move
back to the minutes adjust.
Time of Regeneration
This setting is used to program the time at
which a regeneration is to occur in the delay
mode, or in immediate mode with time clock
backup on. The display will first show “tor” for
two seconds.
After “tor” is shown the display will then
show the default of 2:00 AM (or the current
programmed time of regeneration if already
set). The time can be adjusted in 30 minute
increments by pressing the “+” or “-” keys.
Pressing the “Status” key will save the setting
and move to the next programming step.