3.1» 3,4-Loosoly retain blower hou­

sing support to opposite vibration

damper with capscrew, lockwasher

and flatwasher.

3,1,3,6-Slide exhaust pipe down

through blower housing ^nd through

exhaust pipe u-bolt. Install exha­

ust flange gasket. Retain exhaust

pipe to exhaust flange with an M8

X 50 ram

long and

an M8 x 20 mm

long

socket head capscrew and lockwash-

prs.

3,1,3,^"Retain blower housing and

scroll to blower housing support

(installed in previous step) ^^th

b-20 X ^ inch long bolt and flaL-

washer and a hex nut, flatwasher

and lockwasher. Tighten the hex

nut. Finally, tighten all bolts that

thread into the vlhratlon dampers.

3,1,3,7"Tightcn exhaust pipe u-bolt

hex

niiLs,

3,1,3,8"Retaln cylinder head cover

with four MlO X 20 mill long bolts

and lockwashers. Tighten bolts to

12 foot-pounds. TnsLall all No. 10-

32 screws that retain head cover to

blower housing.