beautypg.com

Generac Power Systems NP Series User Manual

Page 34

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

INSTALLATION

Section 6 - Installation

PRIMEPACT 55C and 55LP Recreational Vehicle Generators

♦ 6.7.2 WIRING

Wiring should be of stranded copper to reduce the

chance that vibration may cause breakage.

• Wire gauge size should be large enough to handle at

least 115 percent of the installed generator's rated
maximum current.

• If neutral conductors are used, they must be the same

size as other leg wires.

Route power supply conductors from generator AC

output leads T1 (red), T2 (white), T3 (black) and the
green ground wire through approved flexible conduit
to the electrical junction box on the compartment

wall.

If flexible metal conduit is used between the genera­

tor and the compartment junction box, the conduit
end that terminates the compartment junction box
must be vapor-sealed. Flexible metal conduit is NOT
vapor tight along its entire length.

From the junction box, route power supply wires

through approved conduit to either (a) double-pole,
double-throw transfer switch, or (b) approved isola­
tion receptacle. Connecting to a transfer switch or
isolation

receptacle

must

prevent

vehicle

electrical

circuits from being connected to two different power
supplies at the same time (such as generator and
dockside power).

• Conductors must be rated 221° F (105° C) or must be

of a larger conductor size.

6.7.3

GENERATOR AC CONNECTIONS___________

Generator AC output leads T1 (red), T2 (white) and T3
(black) come out of the generator as shown in Figure
2.17. Leads T1 (red) and T3 (black) are “hot,” while T2
(white) is the grounded neutral lead. There is also a

green lead that connects to ground in the junction box

of the recreational vehicle.

Figure 6.17

-

Generator AC Output Leads

Line T1 (red) to T2 (white) is protected against overload
by a 20-amp circuit breaker (CBl). Use this line-to-neu-
tral connection separately to operate 120-volt, single­
phase, 60 Hertz, AC loads requiring up to 2,400 watts

(3.6 kW) of power. Line T3 (black) to T2 (white) also is

protected against overload by a 30-amp circuit breaker

(CB2). Use this line-to-neutral connection separately to
operate similar loads. However, be sure the total unit
load does not exceed the maximum rating of the gener­
ator. The neutral line (T2, white) on all units is a

grounded neutral.

A

-------- ii CAUTION il---------------------

Do NOT connect electrical loads in excess of any

circuit breaker rating or you will develop prob­
lems with circuit breaker tripping, which causes a

loss of AC output. Also, do NOT exceed the gener­
ator's rated wattage capacity. Add the watts or

amperes of all lighting, appliance, tool and motor
loads the generator will operate at one time. This
total should be less than the unit's rated
wattage/amperage capacity.

6.7.4 CONDUIT__________________________________

Route the connections between the generator and the

junction box through approved, flexible conduit. The

following general rules apply:

• Cut wiring to the required length and allow extra wire

for junction box connections.

Carefully

prepare

conduit ends to

prevent

sharp

edges from cutting through wiring insulation.

• Route conduit so it does not interfere with generator

movement.

• If you use metallic conduit, vapor seal the end of the

conduit where it enters the junction box. Do this

because flexible metallic conduit is not vapor proof

along its entire length.

6.7.5 ISOLATING DIFFERENT POWER SOURCES

Connections from the junction box must terminate in a
double-pole, double-throw transfer switch (Figure 2.18,
Page 33). An alternate method for isolating different
power

sources

is

by

using

an

isolating

receptacle

(Figure 2.19, Page 33). Whichever method you use, you

must be certain that both power sources are NOT con­
nected at the same time.

32 Generac* Power Systems, Inc.