Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
4. Push the release valve down and forward to release
pressure. Cylinder will return, with the aid of two
- return springs. See figure 7 and copy of label below.
DOWN TO /
^[\
UP TO LOCK
RELEASE /
/ PUMP AND
PRESSURE ^
-y SPLIT
---- 5052
FIGURE 7
CYLINDER RESERVOIR
SCREW AND WASHER
SCREWDRIVER HANDLE
HANDLE
MAINTENANCE
RESERVOIR OIL
1.
Lift the handle on the cylinder mounting assembly
and pull cylinder assembly all the way back to the
— last notch. See figure 8.
2.
Remove the pump handle.
3.
Release the pressure in the cylinder.
4.
Tip the log splitter up so it rests on the wheels and
handle on cylinder assembly. See figure 8.
5.
With a standard screwdriver, remove screw and
washer from cylinder reservoir. See figure 8. If oil
is up to hole, do not add any oil. If not, add oil to
bring level up to hole. Oil capacity is 10 fluid
ounces.
Nuto
H
grade
32,
or
Exxon
L.P.
conventional #150 Hydraulic oil.
FIGURE 8