ACTIVATING THE
BATTERY
1.
Place battery to be filled on bench or
workbench. NEVER activate battery in unit.
Remove vent caps from all cells.
2. Fill each cell carefully using battery grade
1.250-1.265 specific gravity. Sulfuric acid to
be 3/8” above the top of the separators or to
split ring.
3-. Allow battery to set for 20 minutes to I/2 hour.
Add additional acid if necessary to bring it up
to the proper levei.
4. Repiace the vent caps.
5. The battery can now be charged after the 20
minutes setting period. Battery can be SLOW
CHARGED (DO NOT FAST CHARGE) at a
maximum bench rate of 4-5 amperes until the
specific gravity reading is 1.265-1.275. A
charging rate in excess of this will buckle and
warp the positive plates and perforate the
separators. If electrolyte bubbles violently
while charging, reduce charging rate until
excessive bubbling action subsides, then
continue charging until specific gravity is
reached.
A
CAUTION
After battery has been in service,
add only approved water. DO NOT
ADD ACID.
B. TO INSTALL BATTERY
To install the battery in this unit, refer to next
column.
C. MAINTENANCE
1. Check periodically (every two weeks or
before and after charging) to be sure elec
trolyte level is 9/16” above separator
plates. Add only distilled water or good
quality drinking water. NEVER add addi
tional acid or other chemicals to battery
after initial activation.
2. The battery should be checked with a
hydrometer after every 25 hours of
operation. If the specific gravity is less than
1.225 remove battery and recharge.
3. Coat the terminals and exposed wiring with
a thin coat of grease or petroleum jelly for
longer service and protection against
electrolyte corrosion.
4. The battery should be kept clean. Any
deposits of acid should be neutralized with
soda and water. Be careful not to get this
solution in the cells.
D. STORAGE
1.
Charge battery using normal methods.
NEVER store discharged battery as it will
not recover.
2. Store in cold, dry place.
3. Recharge battery whenever the specific
gravity is less than 1.225 before returning to
service or every two months, whichever
comes first.
E. COMMON CAUSES FOR BATTERY FAILURE
ARE:
1. Overcharging
2. Undercharging
3. Lack of water
4. Loose hold downs and/or corroded con
nections
5. Excessive loads
6. Battery electrolyte substitutes
7. Freezing of electrolyte
NOTE
THESE FAILURES DO NOT CON
STITUTE WARRANTY.
LIMITED WARRANTY
For ninety (90) days of original retail purchase, the
battery carries a limited warranty against faulty
material or workmanship by the battery manufac
turer.
INSTALLING THE
BATTERY
1. Open the hood of the riding mower.
2. Place the battery in the battery case with the
terminal to the front. See figure 4.