Maintenance, Operation 1 – Sears KENMORE 1700 User Manual
Page 9
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
NOTE:
Make sure wall outlet is not controlled by a switch.
operation
1
Set knob to the lowest temperature predicted tor a
24-hour period. Because of differences in house construction
you may want to try a higher or lower setting to achieve proper
humidity.
Change knob settings as outdoor temperature changes
occur.
WARNING:
DO NOT LEAVE KNOB SET ABOVE “+20” OR HU
MIDIFIER WILL RUN CONSTANTLY AND MAY OVER
HUMIDIFY YOUR HOME.
IF SWEATING OF WINDOWS OR WALLS
OCCURS OR IF AIR IS TOO DRY:
Check dial setting. Indicator should point to the lowest 24 hour
temperature. If setting does not agree, readjust knob to proper
number and wait 24 hours for sweating to stop. If dial setting
was correct and conditions have not changed, rotate knob back
and forth from TEST to MINIMUM HUMIDITY SETTING. If hu
midifier goes ON and OFF, control is operating properly.
SPLASH INSIDE HUMIDIFIER:
This humidifier depends on the difference of air pressure between
the supply air plenum and the return air plenum to propel air
through the humidifier. Some furnaces have higher pressures than
others. This could result in air travelling at high speed through
the humidifier. This can cause droplets of water to be picked up
and splashed against the inside of the humidifier case. Eventu-
aily a coating of lime will build up. It could in extreme cases, cause
leaking of water from the humidifier. If possible, operate the fur
nace blower at a lower speed,
TO REDUCE SPLASH:
Partially close the damper located in the collar on the
return air plenum. Some experimenting may be necessary to
find the proper setting.
AIR CONDITIONING - IMPORTANT:
If your furnace has air conditioning (cooling), close the damper
completely during summer months and turn the humidistat to
the Minimum Humidity setting. BE SURE TO OPEN DAMPER
DURING HEATING SEASON.
CAUTION:
Do not use tablets in an attempt to control lime de
posits in this humidifier! Use of tablets may cause
humidifier to splash causing damage to humidifier
or furnace.
maintenance
THiS HUMiDIFIER iS AN APPLIANCE THAT EVAPO
RATES WATER IN LARGE QUANTITIES.
The dissolved minerals normally found in tap water are left as
lime deposits in the humidifier. REGULAR CLEANING is nec
essary to keep the parts free of time deposits. Deposit build
up will reduce humidifier output. Ease of servicing has been
foremost in the design of this humidifier. Service at least every
(4) four weeks during the heating season or more often de
pending on the water conditions.
1.
Unplug transformer.
2.
Close saddle valve.
3.
Remove the front plastic panel and lift up top hinged cover.
4.
Pull out pivot pin and remove float and float arm.
5.
Lift out the media wheel and reservoir.
6.
Pour contents of reservoir down the drain.
7.
Clean lime from all parts using a solution of vinegar and wa
ter, detergent and water, or Sears All-Purpose Humidifier
Cleaner (Stock No. 42-14713).
8.
Remove media pad from inside of wheel and clean thor
oughly,
replace
it
necessary
(Sears
Stock
No. 42-14603).
IMPORTANT: Stretch new media length
wise before placing in wheel.
9.
If the Reservoir has been overflowing, the operating Float
Valve Button may be worn. Remove the operating Float
Valve Button, turn it over and reinsert or replace after both
surfaces are worn (see page 10, Fig. 25).
10. Reinstall reservoir, media wheel with pad, float and pivot pin.
11. Open saddle valve and check water level in reservoir. Adjust