selecting a location
Consider these points as you choose the location for your hu
midifier.
Locate humidifier on supply air plenum (Fig. 1) or return air
plenum. If the humidifier is installed on the return air plenum,
the flexible hose, round opening, is connected to the supply air
plenum.
If furnace is equipped with air conditioning, humidifier should
be mounted above or at slope side of "A” coil to avoid possible
splashing (Fig. 2) of water in reservoir.
Humidifier should be installed so that if the humidifier or any
other connections should leak, the resulting flow of water will
not cause damage. Under no condition is Sears and the manu
facturer to be held liable for any water damage in connection
with this humidifier. Never install humidifier in attic or crawl space
where freezing may occur or leaking will cause water damage
If holes between supply air plenum and return air plenumiFffust
be located more than 36 inches apart (Fig. 1), standai^ inch
round pipe and fittings (not supplied) may be used^m an 8 foot
section of flexible tube No. 281152-05 mawi^ purchased
through the Sears parts department. Mate^dfe needed for this
type installation are available at Sears.
inspection
This humidifier is asdembied
with the bypass di^dfon the left
side (Fig. 3)^Tffis is suitable
for install^ifon as shown in
Fig. 1. IJinis is suitable for your
instatfation, remove parts as
iown under
Disassembly.
^Skip conversion steps A, B,
and D. Start your instaliatlon
with C and then skip to □ 1.
If you require the bypass duct
on the right (Fig. 4), remove
parts as shown under
Disas
sembly
and start with A.
disassembly
•
Remove front cover. Lift top cover to lock position.
•
Pull pivot pin and remove float assembly from valve.
•
Lift out media wheel.
•
Remove water reservoir.
■
conversion
—
(If
required - see
“inspection”
above)
L A
Pull motor bracket and wire bearing support to remove
from lances (Fig. 5).
Motor Bracket Top Flange — Pull Up-
■pWire Bearing Support — Pull Up
•Top Cover
Motor
-Lances