Section 6, Care of your filter, Section 7 – Sears 625.34823 User Manual
Page 19: Other things to know, Spectftcations dimensions
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

SECTION 6
CARE OF YOUR FILTER
KEEP THE FILTER FROM FREEZING
If the filter is installed where it could freeze (summer
cabin, lake home, etc.), you must drain all water from
it to stop possible freeze damage. To drain the filter -
1. Close the shut-off valve on the house main water
pipe, near the water meter or pressure tank.
2. Open a faucet in the filtered water pipes to vent
pressure in the filter.
3. Looking at FIG. 11 on page 13, move the stem in
a single bypass valve to bypass. Close the inlet
and outlet valve in a 3-valve bypass system, and
open the bypass valve.
’
4. Unplug the transformer at the wall outlet.
5. Pull the holding ciip to remove the drain fitting, with
drain hose attached, from the valve.
6. Looking at FIG. 5 on page 9, remove the plastic
clips and pull the adaptors or bypass valve from
the inlet and outlet.
7. Move the filter dose to the floor drain. SLOWLY
and CAREFULLY (the filter is heavy) tip the filter
over so the valve inlet and outlet are over the drain.
Aiiow water to drain from tank. DO NOT REST THE
FILTER ON THE INLET AND OUTLET FITTINGS
OR THEY WILL BREAK.
8. Tip the bottom of the filter up a few inches and hold
until all water has drained. Leave the filter laving
like this until you are ready to use it. Plug the inlet
and outlet with rags to keep dirt, bugs, etc. out.
SECTION 7
OTHER THINGS TO KNOW
SPECtFtCATIONS
DIMENSIONS
TYPE OF FILTERING MINERAL
Aggregate
AMOUNT OF FILTERING MINERAL
1.0 Cu. Ft. (.028 Cu M)
WATER PRESS. LIMITS (Min.-Max.)
20 to 125 PSI (1.4 to 8.4 Kg/Sq/Cm)
MAXIMUM WATER TEMPERATURE
120 F (48.9 C)
MINIMUM WELL PUMP CAPACITY
270 Gal/Hr (1022 Liter/Hr)
MIN. PIPE SIZE TO FILTER
3/4 In. (19MM)
BACKWASH FLOW RATE*
4.5 Gal/Min (17 Uter/Min)
SERVICE FLOW RATE
(at max. pressure drop of 10 psi)
6-6 Gal/Min (25 Liter^in)
CAPACITY
8600 Gal (32553 Liters)
MICRON RATING
25
*at 35 PSI inlet pressure
55"
(139.S cm)
DIA.
»Il—i
(27.9 cm)
T—
Freeboard
18" (45.7 cm}
i______
“D
- '____
iu
Intot-Outht
49"
(124.5 cm)
19.