SECTION 3 STEP BY STEP GUIDES TO INSTALL
ELECTRIC POWER OUTLET FOR YOUR
FILTER
The filter works on 24 volt, 60 Hz electric power. The
included transformer changes standard 120 volt AC
house power to 24 volts. You must plug the transformer
Into a 120 volt outlet only. Be sure the outlet is always
"live” so spmeone cannot turn it off by mistake.
^ « FASTEN THE POWER CABLE AND PLUG IN
THE TRANSFORMER
Looking at FIG. 14, fasten the 2 power cable lugs (1
under each screw) to the transformer as shown.
Tighten both screws, then plug the transformer into
the outlet.
NOTE; When you plug in the transformer, 12:00 AM
and SU begin to flash in the face plate display,
^ Д SANITIZING THE WATER FILTER
' Care is taken at the factory to keep your filter
clean and sanitary. Materials used to make the filter
will not infect or contaminate your water supply, and
will not cause bacteria to form and grow. However, if
sanitizing is needed, do the following.
FIG. 14
CONNECTING TRANSFORMER
Transformer
\\/^\ Power Cable (Hook either lead
' under either transformer terminal.)
_ Press and hold button
^__
until RCHG begins to flash in the face plate
on the face plate
AM
ncHG 12:00
SU
display, starting a backwash.
After 5 to 10 minutes, press
button H] again to start fast
______ _
rinse. Wait about 1 minute. THEN TURN OFF WATER
TO THE FILTER AT THE MAIN SUPPLY VALVE.
Press button d] once more to return the valve to
service.
ij Carefully remove the large plastic clip at the
filter valve inlet (FIG. 7, page 10) and pull the
adaptor out.
NOTE: If bypass valve. Item No. 42/65-3437 is install
ed, or if plumbing is too rigid to move, also disconnect
the outlet side and move the filter away from plumbing.
C.
Put 1 teaspoon (0.1 ounce) of calcium
hypochlorite into the valve inlet as far as
possible.
NOTE: You can buy calcium hypochlorite in tablet or
granular form using trade names such as Perchloron
and HTH.
d.
e.
f.
Carefully reconnect the plumbing.
Turn on the water supply.
Open the nearest filtered water faucet until you
can smell chlorine, then close the faucet.
DO NOT USE WATER FOR ABOUT 45
MINUTES.
Q After the 45 minutes, see step a to start a
backwash. The filter will complete this
backwash in about 35 minutes.
While the filter is backwashing, do step 15. Then
make the timer settings beginning on page 15.
|-|^ When the backwash is over, open filtered
' water faucets until chlorine odor is gone, then
close.
He TURN ON THE GAS (OR ELECTRIC)
* SUPPLY TO THE WATER HEATER AND
LIGHT THE PILOT.
14.