Preparation, Electrical connections, Gas connections – Sears 32025 User Manual
Page 6
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

PREPARATION
Adequate courrterspace must be provided for the unit.
The area should be easy to reach and be lighted with
natural light during the day.
See t he first page for cutout dimensions. Mark the cutout
on the counter. Use a hand or saber saw to make the cut.
ELECTRICAL CONNECTIONS
Call your Electric Company and ask which codes apply
In your area. If there are no codes, you must follow the
NATIONAL ELECTRICAL COOES, ANSI/NFPA NO. 70-
Latest Edition. You can get a copy by writing:
National Fire Protection Association
Batterymarch Park
Quincy, MA 02269
The counter unit cord has a three prong plug and must
be plugged into a properly grounded three hole outlet.
The outlet must be In a standard 120 Volt, 60 Hertz AC
household circuit.
Improper grounding can spark ignition on models so
equipped.
A
Do
not
under
any
circumstances
cut or remove the grounding prong
from the counter unit cord. Failure
to provide proper polarization may
cause shock and fire hazard.
If you do not have a grounded three hole outlet, have an
electrician change your old outlet or install a new one.
To temporarily use a properly polarized and grounded
two hole outlet until a grounded three hole outlet can be
installed, a grounding adapter plug may be used. Have
an electrician test the outlet to be sure it meets require
ments.
PLUG WITH GROUND PRONG
PROPERLY POLARIZED AND
GROUNDED RECEPTACLE
POLARIZED RECEPTACLE
PROPERLY GROUNDED
METAL EYELET
GROUND
PREFERRED METHOD
RECEPTACLE
PLATE
MOUNTING
SCREW
Fig. 2
TEMPORARY METHOD
GAS CONNECTIONS
Cal I your gas suppi ler and ask which codes apply In your
area. If there are no codes, you must follow the NA
TIONAL FUEL GAS CODE, ANSI/Z223.Latest Edition.
You can get a copy by writing:
American Gas Association
1515 Wilson Boulevard
Arlington (Rosslyn), VA 22209
Know where your main gas shut off valve Is.
Shutoff gas supply before removing an old range. Leave
it off until hookup of new counter unit is finished.
See figures on this page for rigid and flexible pipe
hookups. Some local codes do not allow the use of
copper gas pipe. If flexible connectors are alio wed,
a new A.G.A. certified flexible connector is rec
ommended. Never reuse an old connector when
Installing a new unit. A manual shut-off valve, for
the purpose of turning on or shutting off the gas
supply to the appliance, must be installed in the
gas supply line at an accessible location in the
cabinet beiow the counter unit.
We recommend that you use 1/2” gas supply line.
1” FROM BACKWALL
i
T
f—l21/2"-H
FROM CUTOUT
CENTERLINE
LOCATION OF GAS SUPPLY LINE
FIG.3