Leakage Checkpoints
Use tkis guide to check a “Leaking” water heater. Many suspect
ed “Leakers” are not leaking tanks. Often the source of the water
can be found and corrected.
Jf you are not thoroughly familiar with your local gas codes your
water heater, and safety practices, contact the Sears Service
Center to check the water heater.
Troubleshooting
(cont’d)
A CAUTION
Read this manual first. Then before checking the water
heater make sure the gas supply has been turned
“OFF’* *, and never turn the gas “ON” before the tank is
completely full of water.
A CAUTION
Never use this water heater unless it is completely filled
with water. To prevent damage to the tank, the talk
most be filled with water. Water must flow from the hot
water faucet before turning “ON” gas to the water
heater.
Water ar the draft hood is water vapor which has con
densed out of the combustion products. This is caused by a
problem In the vent. Contact the Sears Service Center.
^Condensation may be seen on pipes in humid weather or
pipe connections may be leaking.
О
e
*The primary anode rod fitting may be leaking,
Small amounts of water from temperature-pressure relief
valve may be due to rhemiaJ expansion or high water pres
sure in your area.
*The temperature-pressure relief valve may be leaking at
the tank fitting.
Water ftom a drain valve may be due to the valve opened
slighdy.
e
*The drain valve may be leaking at the tank fitting.
Ф
Combustion products contain water vapor which can con
dense on the cooler surfaces of the tank. Droplets form and
drip into the fire or run on the floor. This is common at
the time of startup after installation and when incoming
water is cold.
Water in the water heater bottom or on the floor may be
from condensation, loose connections, or the relief valve.
DO NOT replace the water heater until a fiiU mspection
of all possible water sources is made and necessary correc
tive steps taken. Leakage from other appliances, water
lines, or ground seepage should also be checked.
NOTE: To check where threaded portion enters tank,
insert cotton swab between jacket opening and fitting.
If cotton Is wet, follow “Draining” instractions in the
"Service and Adjustment” section and then remove fit
ting. Put pipe dope or teflon tape on the threads and
replace. Then follow “Filling the Water Heater”
instructions in the “InstaUation Instructions” section.