MAINTENANCE AND TROUBLE-SHOOTING
MONrrOR CARE
Tighten all parts of the CARDIO FORCE regularly. The CARDIO FORCE can be cleaned with a soft, damp cloth.
Do not allow liquid to come in contact with the monitor. Keep the monitor out of direct sunlight or the LCD dis
play may be damaged.
REPLACING THE BATTERIES
If the display of the Monitor (1) becomes dim, the two
L1154 watch batteries should be replaced. See drawing A.
Remove the upper #6 x 3/8" Screw (16) from the back of the
Monitor (1). See drawing B. Pivot the Pedal Frame (7) as
shown. Remove the lower #6 x 3/8” Screw (16) from the
back of the Monitor. Remove the Sensor Wire (15) from the
back of the Monitor. See the inset drawing. Remove the four
screws from the back cover of the Monitor and remove the
back cover. Push the two old batteries out of the clips, being
sure to note which way each battery is turned. Insert two
new batteries.
Reattach the back cover of the Monitor (1). Plug the Sensor
Wire (15) into the back of the Monitor. Insert any excess
wire into the Frame (6). Reattach the Monitor to the Frame
with the two #6 X 3/8" Screws (16).
ADJUSTING THE MAGNET AND REED SWITCH
If the monitor does not function properly, the Magnet (18) and
Reed Switch (15) should be checked. Pivot the Pedal Frame
(7) until the Magnet is aligned with the Reed Switch. Loosen
the #8 X 3/8” Screw (27) and adjust the position of the Reed
Switch so that there is a 1/8” gap between the Magnet and
the Reed Switch. Retighten the Screw.
LUBRICATING THE CARDIO FORCE
The CARDIO FORCE should be oiled every six months in
the iocations shown at the right. Apply a few drops of light
multi-purpose oil between each of the indicated dome caps
and the frame. Be sure to apply oil to each side of the CAR
DIO FORCE.
8