selecting a location
Consider these points as you choose the location for your
humidifier.
Locate humidifier on supply air plenum (Fig. 1) or return air pie-
num. If the humidifier is installed on the return air plenum, the flex
ible hose, round opening, is connected to the supply air plenum.
If furnace is equipped with air conditioning, humidifier should be
mounted above or at slope side of “A” coil to avoid possible splash
ing (Fig. 2) of water.
Humidifier should be installed so that if the humidifier or any other
connections should leak, the resulting flow of water will not cause
damage. Under no condition is Sears and the manufacturer to be
held liable for any water damage in connection with this humidi
fier. Never install humidifier in attic or crawl space where freezing
may occur or leaking will cause water damage.
If holes between supply air plenum and return air plenum must
be located more than 40 inches apart (Fig. 1), standard 6 inch
round pipe and fittings (not supplied) may be used, or an 8 foot
section of flexible tube No. 28115205 may be purchased through
the Sears parts department Materials needed for this type instaF
lation are available at Sears.
installation
The humidifier is shipped with the block-off panel on the
right side (Fig. 3). This is suitable for installation as shown
In Fig. 1, above. If this is suitable for your installation,
remove parts as shown under DISASSEMBLY.
If you require the block-off panel on the left side (Fig. 4),
start vrith DISASSEMBLY then remove block-off panel from
right flange and install with the same screws on left flange.
FIBER PLENUM DUCTS
NOTE: The mounting screws supplied are for stan
dard installation on sheet metal plenum ducts.
If you have fiber plenum ducts, install the hu
midifier and components with thru-bolts, nuts, and
washers (not supplied). (This fiber duct installa
tion hardware is not supplied and must be pur
chased from you local hardware store.)
CAUTION; Safety glasses should be worn to pre
vent eye injury when installing humidifier.
disassembly
1. Take off front panel by sliding pan^ up and pulling out at
the bottom.
2. Remove corrugated spacer and by-pass boot which con
tains damper, collar & flex tube and tube damp.
3. Remove media pad by lifting bottom edge up slightly and
pulling out.
^