KEEP YOUR DISPENSING SYSTilf^lM-GQOD'WOiKINGORDEB;::
If the dispensing system is exposed to the sun,
replace the solution tubing every 6 months. Re
place the tubing yearly if the system is instalied
indoors.
CLEAN THE STRAINER -- Before filling the tank
with solution, remove the strainer, remove the
threaded fitting from the end of the strainer, then
clean by forcing water backwards through the
strainer.
CHECK THE INJECTION FITTING - The plastic
sleeve on the injection fitting helps to keep it clean
and working. However,check it every few months
to keep it from plugging.
CAUTION: BE SURE TO TURN OFF WATER
SYSTEM PRESSURE BEFORE REMOVING THE
INJECTION FITTING.
Electrical Voltage............ 115 AC
Frequency............................ 60Hz
Amperage..................................37
Max. Pumping Rate per
Hour........................... 0 5 gals. (1.89 Liters)
Max. Pumping Rate per
24 Hours.................... 12 gals. (45.4 Liters)
Max. Water System
Press. ............. ............ 75 psi (5.27 kg/cm^)
Reservoir
Capacity..................... 15 gals. (56.8 Liters)