beautypg.com

Guides to install your solution dispensing system – Sears 625.34929 User Manual

Page 10

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

SpW'

GUIDES TO INSTALL YOUR SOLUTION DISPENSING SYSTEM

SOLUTION INJECTION BETWEEN THE WELL PUMP AND PRESSURE TANK

1. Turn off the electrical power to the well pump
and turn off the gas or electric supply to the water
heater,

2. Open a faucet for a few seconds to bleed off

water pressure, then close,

3. Close the shut-off valve on the main supply pipe
close to the pressure tank

NOTE: If you have a shut-off valve between the

pressure tank inlet and the place you will install the
injection point, you do nothavetodrain water from

the tank Otherwise, drain all water from the tank,

4. Open the drain valve on the well pump, if it has

one.

5. Between the well pump and pressure tank, install

ateefittingas shown in FIG. 6 INSTALLTHETEE

AS SHOWN. SO THE INJECTION FITTING GOES
WITH THE FLOW OF WATER NOT AGAINST IT.

6. Use a reducer bushing as shown, to reduce the tee
to 1/4 in. pipe thread. Use teflon tape or pipe dope on

the threads.

7. Put teflon tape or pipe dope on the threads of the
injection fitting and turn it into the reducer bushing
until tight, DO NOT OVERTIGHTEN. DO NOT
REMOVE THE PLASTIC SLEEVE FROM THE TIP
OF THE INJECTION FITTING. IT IS A WORKING
PART.

8. Set the solution dispensing system in the place
you chose to locate it,

9. Measure for the length of tubing needed to run
from the solution pump discharge fitting, to the
injection fitting. The tubing is stiff, so allow enough
length for longer bends. Cut both ends of the
tubing square with a sharp knife.

10. Remove the nut from the discharge valve {FIG.

6) on the solution pump. Slide the nut over 1 end of
the tubing. Push the tubing onto the tip of the
discharge valve as far as it will go. Then slide the
holding nut onto the valve and tighten it with your

fingers.

11. In the same way as in step 9, connect the other

end of the tubing to the injection fitting.

12. Turn on the electrical power to the well pump

and open the main water supply valve. Open
faucets to let air out of the water system, then close

13. Check your plumbing work for leaks.

14. Turn on the gas or electric supply to the water

heater and relight the pilot.

SEE PAGE 11 TO MAKE THE NEEDED ELEC­
TRICAL CONNECTIONS.

liiciMei

Pump Head
Disciiarge Fitting

10