Troubleshooting, Automatic electronic diagnostics, Manual initiated electronic diagnostics – Sears 625.34842 User Manual
Page 52: Service tech. information 5a. troubleshooting
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

SECTION 5
SERVICE TECH. INFORMATION
5A.
TROUBLESHOOTING
AUTOMATIC ELECTRONIC DIAGNOSTICS
The face plate computer has a self-diagnostic
function for the electrical system (except input
power and water meter). The computer monitors the
electronic components and circuits
for correct operation. If a malfunc
tion occurs, an error code appears
in the face plate display.
СГГ
The chart below shows the error codes that could
appear, and the possible defects for each code.
While an error code appears in the display, all face
plate buttons are inoperable except the SELECT
button. The SELECT button remains operational so
the service person can make the Manual Initiated
Electronic Diagnostics to further isolate the defect,
and check the water meter.
CODE
POSSIBLE DEFECT
MOST LIKELY
LESS LIKELY
Err 01
motor inoperative / wiring harness or connection to switch / position switch / face plate
Err 02
face plate
Err 03
motor inoperative / face plate
Err 04
face plate / position switch
Err 05
face plate
PROCEDURE FOR REMOVING ERROR CODE FROM FACE PLATE:
1 Unplug transformer 2 Correct defect 3 Plug in
transfctrmer 4. Wait for 6 minutes. The errctr cctde will return if the defect was nett cctrrected.
MANUAL
INITIATED
ELECTRONIC
DIAG
NOSTICS
1.
To enter diagnostics, press and hold the SELECT
button until
000
— shows in the display.
TURBINE SWITCHES
nnn_______
1Л1Л1-! ^
О
WATER METER
(A)
SWITCH
(B)
A. The first 3 digits indicate water meter operation
as follows:
000 (steady) = Soft water not in use, and no
flow through the meter.
— OPEN A NEARBY SOFT WATER FAUCET —
000 to 199 (continual) = Repeats display for
each gallon of water passing through the meter.
If you don’t get a reading in the display, with the
faucet open, pull the sensor from the valve outlet
port. Pass a small magnet back and forth in front of
the sensor. You should get a reading in the display. If
you get a reading, unhook the in and out plumbing
and check the turbine for binding.
MOTOR
POSITION
SWITCH
SENSOR
HOUSING
TURBINE
TURBINE
SUPPORT AND
SHAFT
B.
VALVE
OUTLET
The letter (P) and dash (or dashes) indicate POSI
TION switch operation. If the letter appears, the
switch is closed. If the dash shows, the switch is
open.
Use the ON/OFF-HOLD (Recharge Now) button
to manually advance the valve into each cycle
and check correct switch operation.
20