TROUBLESHOOTING GUIDE

W A R N I N G

1

VOLTAGE SOURCES, MOVING PARTS, OR COMPRESSED AIR SOURCES ARE EXPOSED WHEN

REPAIRING THE COMPRESSOR. PERSONAL INJURY CAN OCCUR. UNPLUG THE COMPRES­
SOR AND BLEED OFF ALL AIR PRESSURE BY TURNING THE ADJUSTABLE PRESSURE VALVE

TO THE START POSITION BEFORE ATTEMPTING ANY REPAIRS.

PROBLEM

CAUSE

CORRECTION

Air Leaks

Hose fitting ioose.

Tighten fitting.

Compressor is not deliver­

ing enough air.

Prolonged excessive use of air.

Decrease the amount of atr usa^. Vbur com­
pressor is not large enough for the air

requirement

Restricted arr intake fif^r.

Clean or replace the air intake filter. (See page

7).

Hole in hose.

Replace the hose.

Air leal@.

Tighten fittings.

Restricts Air Intake

Dirty air filter.

Clean or replace

vM\

new flltor. Do net oper­

ate the unit In the spray area.

Compressor wdfP not start

Compressed air is in compres-

pump.

Set the adjustable pressure valve knob at
‘Start” to ret)e>re pressure before starting the
air compressor. (See Operating Procedures

on page 7.)

Motor will not run

Motor otrerioad protection switch
has tripped.

Let motor cool off and the compressor Vkrin
automatically re-start

Fuse

blown,

circuit

breaker

tripped.

1. Qieck ttox tor blown fuse and replace

as necessary. Reset circuit breaker. Do not

use a fuse ck circuit breairer with higher rating

than that specified for your particular branch
circuit

2.

Check for proper fuse. You should be using

a Time Delay fuse.

3.

Check for low voltage problem. See the

“NOTE" on page 7 tor details.

4. Check the extension cord. See page 6 tor
ffidension cord information.

5.

Disconnect the otoer electrical appliances

from circuit or operate the compressor on Hs
own branch cift^íL

Extension cord is wrong length

» gauge.

Check the extension cord. See page 6 for
exterreion ccxd intormafion.

Loose electrical connectons.

Check wiring connection Inside terminal box
area

Faulty motor.

Hare chedffid at a local Sears servicre center

High Discharge lussurie -
cannot be adjusted lower

Adjustable

pressure valve

not

functioning.

W A S H I N G