TROUBLESHOOTING

PROBLEM (SYMPTOMS) POSSIBLE
CAUSES

———————————————————————

Won’t Start

*Low Oil Level.

*Fouled spark plug.

*Out of fuel.

*Start switch in Off position.

*Fuel valve turn off.

*Plugged fuel filter.

———————————————————————

Voltage too low

*Engine speed is too low.

*Generator overloaded.

*Defective stator.

*Defective rotor (field).

*Defective Capacitor.

———————————————————————

Circuit Breaker

*Defective load.

Trips

*Defective receptacle.

*Excessive Load.

———————————————————————

Voltage too high

*Engine speed is too high.

———————————————————————

Generator

*Overloaded.

overheating

*Insufficient ventilation.

———————————————————————

No output voltage

*Short in load (disconnect).

*Tripped or defective circuit

breaker.

*Broken or loose wire.

*Defective receptacle.

*No residual magnetism

(in generator).

*Defective stator.

*Defective rotor (field).

*Shorted capacitor.

*Shorted diodes on rotor.

*GFCI Receptacle tripped.

———————————————————————

SPECIFICATIONS

WT3000H/C

Generator manufacturer

WINCO Inc

Part number

15041-07

Rotor resistance

0.87 Ohms

Stator resistance G1-N.

0.55 Ohms

Cap winding resistance

1.75 Ohms

Capacitor

40.0 mF

Capacitor part number

15051-000

Engine manufacturer

HONDA

Engine model number

GX160UT2

Type

VA2 NH1

Spark plugs

BPR6ES (NGK)

Air filter

17210-ZE1-822

Spark plug gap

0.00 in

Oil capacity

.61 qts.