LOCATING STOVE
Failure to follow these minimum clearance require-
ments may result in an unsafe installation and could
cause a fire.
Installation of this stove must comply with the latest
edition of NFPA 211 for reduced clearances and/
or your local building code rulings. Use whichever
minimum dimensions are the LARGEST.
9.
NEVER OPERATE THIS STOVE WITHOUT THE
ASH CLEANOUT COVER IN PLACE OR WITH
THE ASH DRAWER REMOVED – very dangerous
operating conditions could result.
10. This stove meets U.S. Test Standard: UL 1482-2010
& Canadian Standard: ULC-S627-00.
11. Always locate stove to provide a source of fresh
air into the room where the unit is installed.
Failure to do so may result in air starvation of other
fuel burning appliances and the possible develop-
ment of hazardous conditions.
12"/30.5cm
12"/
30.5cm
CORNER CLEARANCES
Fig. 11 – Top View
Minimum Corner Clearances
from Combustible Surfaces
CAUTION: REPLACE FIREBRICKS BEFORE
FIRING WOODSTOVE. POSITION FIREBRICKS
SO NO GAPS REMAIN BETWEEN BRICKS.
C A U T I O N : K E E P F U R N I S H I N G S A N D
OTHER COMBUSTIBLE MATERIALS AWAY
FROM THE STOVE AND OUTSIDE MINIMUM
CLEARANCES.
Fig. 12d – Side View
Fig. 12c – Front View
Fig. 12b – Side View
Fig. 12a – Front View
Minimum Clearance Dimensions
from Combustible Surfaces
Minimum Clearance Dimensions
from Combustible Surfaces