Ups gx-50/60/65 – TruTrak DFC Install Manual User Manual
Page 7

TruTrak Flight Systems
DFC Autopilot Installation Manual
5
May 2006 Printing
Power 430/530 up and turn it on while holding down the ENT key. Release the ENT key when the display activates. After the
data base pages, the first page displayed is the MAIN ARINC 429 CONFIG page. While in Configuration mode, pages can be
selected by ensuring the cursor is off and rotating the small right knob. To change data on the displayed Configuration Page,
press the small right knob (CRSR) to turn on the cursor. Turn the large right knob to change between data fields. Turn the large
or small right knob to change a field that the cursor is on. Once you have made the desired selection, press the ENT key to
accept the entry.
With the MAIN ARINC 429 CONFIG page displayed, on the row labeled OUT, select SPEED Î Low
and DATA ÎARINC 429.
Advance to the MAIN RS232 CONFIG page.
On the row labeled CHNL1, select OUTPUT Î Aviation.
Note that for the Garmin units, the autopilot will need to be set for 9600 baud.
.
UPSAT GX-50/60/65 connections to TruTrak autopilot
37-Pin Connector
on UPSAT
GX-50/60/65
Signal Name
(UPSAT)
Signal Name
(TruTrak)
P101 on
TruTrak Autopilot
14 CDI
+L
CDI
LEFT
21
13
CDI +R
CDI RIGHT
22
Use pin 5 – TxD1 – if GX has no
GPSS
5
or
22
Use pin 22 – TxD2 – if GX has
GPSS
Primary Serial
Input
25