Parameters and Settings

CAUTION: Use care when accessing and adjusting your indicator’s
parameters. Several parameters can be accessed that, if altered, will
change your indicator’s operations.

To access and adjust the TS-700 SS parameters:

Press the PRINT and HOLD keys. “C” will display. Release the keys.
“C08” will display, with the 8 flashing. The digit flashing is the active
digit, and can be adjusted up or down by using the ZERO/UP
ARROW or TARE/DOWN ARROW key. Use the KG-LB/LEFT
ARROW key and the TARE/RIGHT ARROW KEY to change which
units digit is active (flashing).

TIP: You can move forward through all parameters and view
the settings by pressing the PRINT/ENTER key repeatedly.


Navigate to the setting parameter you wish to adjust and use the
arrow keys to change the settings values. Press the PRINT/ENTER
key to accept your settings, then press the TOTAL/EXIT key.

EXAMPLE: To adjust the date setting in parameter C16:
-

With “C08” flashing, use the down arrow key to reduce the
flashing 8 to 6. Use the left arrow key to make 0 the active digit.

-

Use the up arrow key to increase the 0 to 1.

-

“C16” will display. Press the PRINT/ENTER key.

-

The display will show digits for month, day and year. Use the
arrow keys as discussed above to navigate to and change the
digits.

-

Press the PRINT/ENTER key to accept your settings.

-