Load cell connections – Triner Scale TS 700-SS User Manual
Page 5

3
Load Cell Connections
The indicator can connect with a maximum of eight of 350Ω load cells, 4
wire or 6 wire configurations.
Excitation voltage for the load cell is 5VDC, the largest output current
120mA.
Terminal Block on Circuit Board:
Circuit Board Terminals Load cell
+EXC + voltage
+SIG
+ output signal
HD ---------
Shielded wire
- SIG - output signal
-EXC -SIG HD +SIG +EXC - EXC - voltage