14

Bit2

Bit1

Bit0

unit

0

0

0

Kg or lb

0

0

1

g

0

1

0

t

Bit 3

printing=1

Bit 4

Extend

display=1

Bit 5

Constant 1

Bit 6

Constant 0


PC Computer Continuous Sending Format

,

,

CR LF


S 1 S 2 S 3 Data

S 4

S1:

weight status, ST= standstill, US= not standstill, OL= overload

S2:

weight mode, GS=gross mode, NT=net mode

S3:

weight of positive and negative, “+” or ” –“

S4:

“kg” or “lb”

Data:

weight value, including decimal point

CR:

carriage return

LF:

line feed

Serial Interface Reception Command

RS232COM serial interface can receive simple ASCII command.
Command word and role as follows:

Command

NAME

Function

T

TARE

Save and clear tare

Z

ZERO

Zero gross weight

P

PRINT

Print the weight

R

G.W/N.W

Read gross weight or net weight

C

Kg/lb

Kg/lb conversion

G

G.W

Check gross weight at net weight mode