10.

3

FRAMING DIAGRAM FOR BATHTUB REPLACEMENT SHOWER

Note that for ALL installations, Thin-Set mortar is used in the Drain Core area. Fill the drain core only 2/3rds full

of Thin-Set. Do not overfill as this will prevent proper floor draft and may push the drain area up causing the unit

not to drain properly. Make sure you block off the drain core to prevent the Thin-set from escaping to the floor

below.

Before beginning final installation, it is ESSENTIAL that the sub floor in the installation area be completely clean.

It must be free of all dirt, trash, oil, grease, water and other contaminants that may affect adhesion.

Thoughly clean the area before proceeding with the shower installation.

After blocking the drain core, apply the appropriate amount of Thin-Set in the drain core area. Then appy the

Thin-Set mortar to the installation area, as shown in Figure 2. Apply a wide bead of 3M polyurethane adhesive

(or equivelent) at the front where the shower threshold will be located.

Carefully lift the shower base into the framing alcove. Guide the shower drain pipe with a hammer handle or

equivelent. The entire bottom of the shower must be in contact with the Thin-Set mortar. The front threshold must

seat into the heavy bead on 3M adhesive.

11.

When installing showers without the factory Easy Base, wet Thin-Set mortar must be appled to the sub-floor to

provide support of the shower base. The Thin-Set should be applied immediately before the shower base is set

in place. This Thin-Set should be thick enough to assure it will contact the bottom of the shower, but be plyable

enough so it may be dispalced as the shower is leveled.

Note that for ALL installations, 3M Polyurethane Adhesive (or equivelent) is use to adhere the shower threshold

to the sub-floor.

Apply a thick bead of 3M Polyurethane Adhesive (or equivelent) along the sub-floor where the shower threshold

will be located as illustrated in Figure 2.

After blocking the drain core, apply the apropriate amount of Thin-Set in the drain core area. Then appy the

adhesive to the installation area as shown in Figure 3. Use a notched trowel to spread the adhesive. Apply a wide

bead of 3M polyurethane adhesive (or equivelent) at the front where the shower threshold will be located.
Carefully lift the shower base into the framing alcove. Guide the shower drain pipe with a hammer handle or

equivelent. The entire bottom of the Easy Base including the threshold must be in full contact with the Construction

Adhesive.

12.
13.

14.

15.

15.

16.

Figure 2

Blocking

between studs

to secure the

mounting flange

Box out for

sub floor

plumbing.

10” x 10” core

size required

Example of Mortar Thin Set Pattern

3M polyurethane adhesive

heavy bead applied under

the shower threshold

Include drain core

(Without Easy Base)

Laticrete thin set

mortar troweled

under shower.

Installation of Units Without Easy Base

Note that thin set

mortar must be

applied to the drain

core area

Installation of Units With Factory Easy Base