Status Information
M-864D connection establishment status
Status data is transmitted from the M-864D when the TCP connection is established.
DFH, 01H,01H
Level Meter Status Format
The M-864D transmits the current status data when level meter status changed in Level Meter
Status Notification started.
E6H, 04H, 00H,
00H: Mono In channel
01H: Stereo In channel
02H: Mono Out channel
When Channel Attribute=00H: 00H - 07H (Mono In channel 1 – 8)
When Channel Attribute=01H: 00H - 03H (Stereo In channel 1_L – 2_R)
When Channel Attribute=02H: 00H - 03H (Mono Out channel 1 – 4)
00H – 48H: (-48dBu - +24dBu(PEAK), See: “Level Meter Table”)
Example of the Level Meter status data of Mono In 1 changes to 0dB
E6H, 04H, 00H, 00H, 00H, 30H
ZM Remote Controller Connection Status Format
The M-864D transmits the current status data when the ZM Remote Controller Connection
Status changed in Auto Status Notification started.
E6H, 04H, 01H, ,
00H – 0FH: ZM Address Number 0 - F
00H: None
01H: ZM-9011
02H: ZM-9012
03H: ZM-9013
04H: ZM-9014
00H: Disconnection
01H: Connection
Example of the connection status data of Address 0’s ZM-9011 changes to disconnect