Warning, Connections, Speaker connections – Toa A-1812 User Manual

Page 7: Remote power on/off control connection

background image

7

Be sure to attach the supplied terminal cover after connection completion. Because high voltage is

applied to the speaker terminals, never touch these terminals to avoid electric shock.

5. CONNECTIONS

5.1. Speaker Connections

C

C

4 16Ω

DIRECT

100 V

INPUT

ZONE 2

100 V

ZONE 1

100 V

Total impedance
330 Ω (A-1803)
167 Ω (A-1806)
83 Ω (A-1812)

4 – 16 Ω

100 V line

100 V line

100 V line

Notes

• Both the 4 – 16 Ω and 100 V terminals cannot be used

at the same time.

• Impedances indicated in the figures represent the total

speaker system (load) impedances.

24 V

C

C

4 16Ω

DIRECT

100 V

INPUT

ZONE 2

100 V

ZONE 1

100 V

24 V

WARNING

5.2. Remote Power ON/OFF Control Connection

The optional P-1812 PA Amplifier's power can be remotely switched ON or OFF with the power switch
operation of the A-1800 series. (This remote control operates only when the P-1812's power is OFF.)
Make the Remote IN-OUT terminal connections as shown below.

REMOTE OUT

A-1803
A-1806
A-1812

REMOTE IN

CONTROL

EMER-

GENCY

P-1812

REMOTE IN

CONTROL

EMER-

GENCY

P-1812