Stop, Single, dual & topside systems, For infrared systems see page 3) – Sure Heat CVS303 Natural Gas Conversion Kit User Manual
Page 2

BEFORE proceeding with these instructions
verify the type of log set you have. Is it a DUAL
BURNER Set (Models MO18NG, MO24NG,
SH18NG, SH24NG, CSO30NG) OR an
INFRARED Set (Models GO18TIR or GO24TIR)?
1. If a DUAL BURNER Set proceed with the
instructions beginning below through
page 3.
2. If an INFRARED Set proceed with
instructions starting on page 4 continuing
through page 5.
SINGLE, DUAL & TOPSIDE SYSTEMS
(For Infrared Systems See Page 3)
INSTALLATION OF NATURAL GAS PILOT VALVE
This Safety Pilot Kit contains a Control Valve certified by C.S.A., which provides a safe and convenient way to
ignite your energy efficient gas log set.
Note: Use pipe compound on all male threads to seal joints.
A. This Safety Pilot Kit contains a Natural Gas Orifice and L.P. Gas
hardware. Instructions are packaged separately in this kit.
B. Attach the 3/8” Natural Gas Orifice (Part #20a or #20b) through the
Burner Pan to the Burner Bar using the 3/8” Locknut supplied only
with Dual and Topside Burner log sets. When installing a single burner
log set, a 3/8” locknut is not used. Be sure the small drill hole on the
3/8” Natural Gas Orifice is facing the gas control valve and the large
hole is facing the burner pan. (See Figure 1 & 2)
C. Connect a 3/8” female elbow (Part #19) to the Natural Gas Orifice.
(See Figure 3)
D. Connect the 3” Pipe Nipple (Part #18) to elbow. (See Figure 4)
E. Connect the second 3/8” female elbow (Part # 19) to the 3” Pipe Nipple.
(See Figure 5)
STOP
Figure 1
Figure 2
Figure 3
Figure 4
Figure 5