Troubleshooting – Sure Heat VFMP Vent-Free User Manual
Page 11

TROUBLESHOOTING
Problem
Cause
Corrective Action
• No Pilot ignition
- pilot valve not on
- turn valve to "PILOT" and depress,
keep match near pilot burner until
ignition.
- gas line not clear
- inspect supply lines for tube kinks or
obstructions.
- air in gas line
- turn valve to "PILOT" and depress,
keep match near pilot burner until
ignition.
- allow air to purge through the line,
may take up to (5) minutes.
- no gas supply to fireplace
- check to see if the fireplace is hooked
to the gas supply.
- no L.P. gas
- fill tank
- main shutoff valve closed
- turn valve on
• Inadequate flame
- valve partially closed
- open valve fully
- gas line obstruction
- inspect burner for tube kinks or
obstructions.
• Unit shuts off
- thermocouple is overheating
- reposition logs to keep main burner
flame off the thermocouple assembly.
- ODS needs to be cleaned
- Please see the maintenance section
on how to properly clean the ODS.
• Unit ON/OFF issues
- unit will not turn "ON"
- After the pilot has been lit make sure
to wait 2-3 minutes for flame to
appear.
- make sure to only press button on
remote ONCE and wait for soft beep
and the flame will appear.
- unit will not turn "OFF"
- make sure to only press the button on
remote ONCE, wait for soft beep, after
5 seconds the flame will go out and
the unit will be "OFF" but the pilot light
will still be "ON".
- if you want to completely turn "OFF"
the unit make sure to turn the pilot
control knob to "OFF" and the remote
sensor switch to "OFF".
• Remote control
- low battery detection
- when the transmitter/receiver
transmitter/receiver
(transmitter/receiver)
batteries are low, depressing the
ON/OFF key the light intensity of
the LED is weak to alert of a low
battery condition before losing
battery power at all. As soon as the
Page 11