GAS REQUIREMENTS

L.P. Gas Installation

Jenn-Air Gas Grills that are set to operate with L.P. gas come with a high capacity hose and regulator

assembly. This assembly is designed to connect directly to a standard 20 lb. L.P. cylinder.

Attach the gas hose assembly to the brass 3/8 flared fitting on the under side of the grill. Tighten securely and

attach other end to the propane tank. (sold separately) (See Fig. 12)

L.P. Tank Information

Never use a dented or rusted L.P. tank or cylinder with a damaged valve.

The L.P. cylinder must be provided with a shut-off valve terminating in an L.P. gas supply cylinder outlet

specified, as applicable, for connection No. 510 in the standard for compressed gas cylinder valve outlet and

inlet connection ANSI/CGA-V-1. Cylinders must not be stored in a building, garage, or any other enclosed

area. (The L.P. cylinder must have an overfill protection device on it.)

The L.P. Gas supply cylinder must be constructed and marked in accordance with the specifications for L.P.

gas cylinders of the U.S. Department of Transportation (DOT) or the National Standard of Canada,

CAN/CAS-B339, “Cylinders, Spheres and Tubes for the Transportation of Dangerous Goods.”