G E N E R A L D E S C R I P T I O N
The SPECIALTY CONCEPTS SYSTEM (SCS) is a versatile, industrial quality charge
controller for the efficient use of photovoltaic energy and the protection of expensive
batteries.
The SCS is a series-relay battery charge controller using mercury relays, remote
temperature compensation, adjustable charging set-points, low-voltage load
disconnect, circuit breakers, and digital metering. Lights indicate "CHARGING" and
"LOAD DISCONNECT" conditions and the meter displays battery voltage, charging and
load current, and current from an external shunt.
F E A T U R E S
CHARGE REGULATION
•
Available for 12,24,36 or 48 volt systems
•
50 amp charge current: SCS/50
•
90 amp charge current: SCS/90
•
Two-step, series charging, 12,24 v
•
Single step, series charging, 36,48 v
•
Adjustable charging set-points
•
Temperature compensation
LOW-VOLTAGE LOAD DISCONNECT
(LVD)
•
30 amp LVD, 12 volt
•
20 amp LVD, 24 volt
•
15 amp LVD, 36 and 48 volt
•
Adjustable disconnect set-points
•
Manual override switch
MOUNTING
•
Indoor wall mount enclosure (standard)
•
Outdoor enclosures (optional)
MONITORING
•
Digital volt / amp meter
•
“CHARGING” light
DESIGN FEATURES
•
Mercury Relays
•
Array, battery and load circuit breakers
(providing over-current protection and
manual disconnects)
•
Maximum array usage
•
Reverse polarity protection
•
Reverse leakage protection
•
Lightning protection
•
Input noise suppression
•
Remote battery voltage sense
•
“LOAD DISCONNECTED” light