Sc3/15 problems – Specialty Concepts SC3/15 User Manual
Page 15

SC3/15 PROBLEMS:
- Refer to this chart and the SC3/15 PROBLEM NOTES (next
page) to help diagnose potential problems based on the
SC3/15 readings
CASE
BATTERY METER
PANEL METER CHARGE
LIGHT
OTHER
SC3/15
NOTE
(Next page)
1
→
→
No Volts (9 on meter)
Day/Night
See Note 1
(next page)
2
→
→
No Volts (9 on meter)
Night only
See Note 2
3
→
→
Voltage 9-12
No amps
OFF
Day time
See Note 3
4
→
→
Voltage 14.7 - 15.0
See Note 4
5
→
→
Voltage meter less than
actual battery voltage
See Note 5
6
→
→
Voltage meter higher
than actual battery
voltage
See Note 6
7
→
→
Voltage reading erratic
See Note 7
8
→
→
No amps
ON
Day time
See Note 8
9
→
→
Turns OFF
(too soon)
Day time
See Note 9
10
→
→
ON - at night
See Note 10
11
→
→
Panel meter
moving rapidly
Charge light
may also be
going on and
off rapidly
See Note 11
12
→
→
Current meter less
than expected
panel current
See Note 12
13
→
→
Changing to
ON or OFF
Front fuse
being
touched or
taken out
See Note 13
14
→
→
SC3/15
buzzing
See Note 14
15
→
→
SC3/15
hot
See Note 15