I N S T R U C T I O N M A N U A L • M O D E L F M P O W E R S U P P LY
37
The keypad is not functional during the time a printout is being made until a
short audible tone is heard and the LCD returns to system status “READY.”
Printing can be stopped at any time by pressing any key. The printer will
continue printing, however, until the data stored in the buffer has been printed.
Time axis plot lengths of 250 ms, 500 ms, 1 second, 5 seconds and 10
seconds are available for printout. The time axis desired must be specified
prior to the assembly cycle, as follows.
Press the INFO key five times until the following display appears on the LCD
screen:
The red LED in the corner or the CE key indicates that it is functional and
therefore, the displayed value can be cancelled and changed.
Press the CE key and then key in the appropriate numerical code (see below)
for the Time Axis Plot Length desired. Acknowledge the entry by pressing the
ENTER key or wait 30 seconds for automatic acceptance.
GRAPH HEADER
In addition to cycle parameters, the printout will also include readings for Air
Pressure, Cal Pulse, Booster Gain and Horn Number. These values may be
entered through the keypad. The printout readings are reference values only;
i.e., if the gauge pressure setting reads 45 psig and the printout reads
“PRESSURE 20 PSIG”, the parts will be welded with 45 psig. The same
applies for “Booster Gain” and “Horn Number.”
G R A P H T I M E A X I S
CODE
TIME AXIS LENGTH
02
250ms
05
500ms
10
1 sec
50
5 sec
99
10 sec