Sonics FM User Manual
Page 23

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
22
I N S T R U C T I O N M A N U A L • M O D E L F M P O W E R S U P P LY
Press the ENTER key or any other key to enter the new Force Trigger set
value, or wait 30 seconds for automatic acceptance.
The Force Trigger (FT) value can only be set or changed when the Force
Triggering (FT) mode is in effect. It is not operational when the Time Delay
Triggering function (T1) has been selected. Attempts to access FT by
depressing the F Trigger Key when the Time Delay Triggering (T1) function is
in effect will result in this display:
If the required coupling force is not reached because air pressure is not
sufficient, the head will retract after five seconds and the following message
will be displayed:
An assembly cycle can be completed only when the fault has been corrected,
either by increasing gauge pressure or decreasing the Force Trigger value.
The actual horn coupling force can be determined (Model 1098 only) by
following the procedures explained on page 41.
F O R C E - T R I G . M O D E O F F
F O R C E M I S S I N G