beautypg.com

Sonics FM User Manual

Page 23

background image

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

22

I N S T R U C T I O N M A N U A L • M O D E L F M P O W E R S U P P LY

Press the ENTER key or any other key to enter the new Force Trigger set

value, or wait 30 seconds for automatic acceptance.

The Force Trigger (FT) value can only be set or changed when the Force

Triggering (FT) mode is in effect. It is not operational when the Time Delay

Triggering function (T1) has been selected. Attempts to access FT by

depressing the F Trigger Key when the Time Delay Triggering (T1) function is

in effect will result in this display:

If the required coupling force is not reached because air pressure is not

sufficient, the head will retract after five seconds and the following message

will be displayed:

An assembly cycle can be completed only when the fault has been corrected,

either by increasing gauge pressure or decreasing the Force Trigger value.

The actual horn coupling force can be determined (Model 1098 only) by

following the procedures explained on page 41.

F O R C E - T R I G . M O D E O F F

F O R C E M I S S I N G