1 registering method name and binary file, 2 configuring arguments, 3 configuring target agent – Solvline LemonIDE Ver 1.0e User Manual
Page 31

LemonIDE
TM
User’s Guide
5.4.1 Registering Method name and binary file
Select “Main” tab and add name & path for executable binary file.
Name
: Method’s alias
Project
: The name of the project which binary file is located
C/C++ Application
: Binary file to be executed
As shown in the image above, folder under the project directory may be added with
executable binary file name (“Eddy_Apps/hello”), or “Browse” may be used to add its
absolute path (“C:\filesystem_2.1.x.x\src\Eddy_APPs\hello”).
5.4.2 Configuring Arguments
Select “Arguments” tab and enlist necessary arguments when executing binary file.
5.4.3 Configuring Target Agent
Select “Target Agent” tab and input IP address and port number for target device, Eddy
.
Port number is fixed to 2004 on Eddy modules, so do not alter the port number.
5-7