Mounting and Connecting the SAS-Junction Box (SAS-JB)
Multiple SAS-1 units may be connected to a single cabinet controller and communicate over a
single home run link using RS-422 or wireless. When using a cabinet controller such as
SmarTek Systems’ T-BOX, the number of SAS-1 units connected via a single home run cable is
only limited by power supply considerations and the communication polling period. When
connected via wireless, the number of SAS-1 units that share the same wireless link is only
limited by the communication polling period.
Sign Bridge
Lanes
Install Bracket Here
Up Approximately 10 to 15 Degrees
Moves the SAS Coverage Pattern Away
from the Sign Bridge (in Down Road Direction)
Direction of Travel
At Least
30 Ft.
SAS-1