Slant/Fin GXH-190 User Manual
Page 15
GALAXY
15
OPTIONAL FEATURES Continued
RESTORE FACTORY DEFAULT SETTINGS
To restore all features to the factory default settings (see following chart for default settings)
1. Turn the LO TEMP dial to access the Program Mode – indicated in the display as
Pro
2. Turn the HI TEMP dial to select feature
dEF
3. Push the Test/Settings Button to to reset all features to the default settings.
4. Reset LO TEMP and HI TEMP settings to desired temperatures (see page 12)
Dial
Setting
Feature
Options
Description
Default
Setting
Record
Your
Settings
1
Thermal Pre-Purge
OFF
On
Purge Inactive
Purge Active
OFF
2
Fahrenheit or Celsius
F
c
Degrees Fahrenheit
Degrees Celsius
F
3
LWCO Manual or
Automatic Reset
A
b
Automatic Reset
Manual Reset
A
4
Circulator Options
A
b
C
Circulator operation on T/TV call only
Circulator operation on I1/I2 call only
Circulator operation on call from either
A
Circulator Hold Off
Circulator Hold Off – Active
Circulator Hold Off – Inactive
Not available
on this control
Not available
on this control
Low Water Cut-Off
Function
Low Water Cut-Off ON
Low Water Cut-Off OFF
dEF
Restore Factory
Defaults
Y
n
Restore Defaults
Do Not Restore Defaults
n
*
SEE PAGE 12 FOR ADDITIONAL SETTINGS
*: “Circulator Hold Off” feature would be “Active” if defaults are restord. Turn it OFF (Inactive) if required.
Y