Wire feed motor does not run (mig welding only) – Chicago Electric 95424 User Manual
Page 39
IMpORtAnt!
be CERtAIn to shut off the Welder, disconnect it from power, and discharge the torch to
ground before adjusting, cleaning, or repairing the unit.
SKU 95424, 95629
for technical questions, please call 1-800-444-3353.
Page 39
If the steps above do not solve the problem or if the repairs involved are too
complex, contact a qualified technician.
tROUbLEsHOOtInG (continued)
Wire feeds, but shielding gas does not flow (MIG welding only)
pOssIbLE CAUsEs AnD sOLUtIOns
Empty Gas Cylinder:
Check gas cylinder.
nozzle plugged:
Clean nozzle. If damaged, replace.
Regulator or cylinder valve closed:
Make sure both valves are adjusted properly.
Gas line blocked:
Check external hose, and hose within Torch cable.
Gas solenoid broken or not connected properly:
Have a qualified technician check/replace.
1.
2.
3.
4.
5.
Electrode fuses to Work (stick/Arc welding, model 95424, only)
pOssIbLE CAUsEs AnD sOLUtIOns
Electrode too close to workpiece:
Hold electrode slightly farther from workpiece.
Moist or damaged electrodes:
Use dry electrodes that have been stored correctly.
1.
2.
Wire feed motor does not run (MIG welding only)
pOssIbLE CAUsEs AnD sOLUtIOns
If beeping is heard, the wire is likely jammed somewhere in the torch, cable, or
wire feed mechanism.
Carefully examine welding wire and welding wire route to determine the cause of the
jam. Whenever possible, keep the welder off while the jam is being remedied to help
prevent injury when the wire restarts.
(Model 95424 only.) Wire feed speed Knob (3C) in stick (arc) position.
Change knob setting to proper speed.
1.
2.