beautypg.com

Pitch bend change, Program change, A-6 midi data format – Casio CELVIANO AP45ES1C User Manual

Page 48: Rpn (registered parameter numbers)

background image

A-6

MIDI Data Format

430A-E-090A

p

p

.......

P

rogram Number = 00H to 7FH

Send

Pr

ogram Change messages ar

e sent when you select a tone on

the instr

ument.

Pitch Bend Change

Format

Byte 1

Byte 2

CnH

ppH

n

.........

V

oice Channel Number = 0H to FH (Ch1 to Ch16)

ll

.........

Pitch Bend Change LSB = 00H to 7FH

m

m

....

Pitch Bend Change MSB = 00H to 7FH

Byte 1

Byte 2

B

yte 3

EnH

llH

mmH

Filter Cut Off Frequency

NRPN MSB = 01H

NRPN LSB = 20H

Data Entry MSB = mmH

m

m

....

Filter Cut Of

f Fr

equency = 00H to 40H to 7FH (-64 to 0 to

+63)

Recognition

When the instr

ument r

eceives this message, the pr

eset Filter Cut

of

f Fr

equency value for the tone is changed to the value that

corresponds to the data entry MSB of the r

eceived message. Ther

e

is no change when the value of the data entry MSB is 40H(0).

Filter Resonance

NRPN MSB = 01H

NRPN LSB = 21H

Data Entry MSB = mmH

m

m

....

Resonance= 00H to 40H to 7FH (-64 to 0 to +63)

Recognition

When the instrument r

eceives this message, the pr

eset Filter

Resonance value for the tone is changed to the value that

corresponds to the data entry MSB of the r

eceived message. Ther

e

is no change when the value of the data entry MSB is 40H(0).

Filter/AMP

Envelope

Attack T

ime

NRPN MSB = 01H

NRPN LSB = 63H

Data Entry MSB = mmH

m

m

....

Filter/AMP

Envelope

Attack T

ime = 00H to 40H to 7FH

(-64 to 0 to +63)

Recognition

When the instr

ument r

eceives this message, the pr

eset Filter/

AMP

Envelope

Attack T

ime value for the tone is changed to the

value that corr

esponds to the data entry MSB of the r

eceived

message. There is no change when the value of the data entry

MSB is 40H(0).

Filter/AMP

Envelope Decay T

ime

NRPN MSB = 01H

NRPN LSB = 64H

Data Entry MSB = mmH

m

m

....

Filter/AMP

Envelope Decay T

ime = 00H to 40H to 7FH

(-64 to 0 to +63)

Recognition

When the instr

ument r

eceives this message, the pr

eset Filter/

AMP

Envelope Decay T

ime value for the tone is changed to the

value that corr

esponds to the data entry MSB of the r

eceived

message. There is no change when the value of the data entry

MSB is 40H(0).

Filter/AMP

Envelope Release T

ime

NRPN MSB = 01H

NRPN LSB = 66H

Data Entry MSB = mmH

m

m

....

Filter/AMP

Envelope Release T

ime = 00H to 40H to 7FH

(-64 to 0 to +63)

Recognition

When the instr

ument r

eceives this message, the pr

eset Filter/

AMP

Envelope Release T

ime value for the tone is changed to the

value that corresponds to the data entry MSB of the r

eceived

message. Ther

e is no change when the value of the data entry

MSB is 40H(0).

RPN (Registered Parameter Numbers)

Format

Byte 1

Byte 2

Byte 3

BnH

65H

qmH (MSB)

BnH

64H

qlH (LSB)

n

..........

V

oice Channel Number = 0H to FH (Ch1 to Ch16)

q

m

.......

M

S

B

o

f R

P

N

q

l

.........

LSB of RPN

Recognition

RPN messages not defined by the instr

ument can also be

received, but subsequent data entry values after undefined

RPN messages ar

e ignor

ed.

After the MSB and LSB of an RPN ar

e r

eceived and the

applicable contr

ol parameters settings ar

e made, the value is

set by r

eceipt of the MSB of the subsequent data entry

. The

data entry LSB is ignor

ed.

Send

An RPN is sent whenever an operation that changes the

parameter assigned to the RPN is performed.

Pitch Bend Sensitivity

RPN MSB = 00H

RPN LSB = 00H

Data Entry MSB = mmH

m

m

....

Pitch Bend Sensitivity = 00H to 18H (0 to 24 semitones)

Recognition

The data entry LSB is always ignor

ed.

Master Fine T

uning

RPN MSB = 00H

RPN LSB = 01H

Data Entry MSB = mmH

Data Entry LSB = llH

m

m

l

l

....

M

aster Fine T

uning = 00 00H to 40H 00H to 7FH 7FH (-

100 to 0 to +99.99 cents)

Master Coarse T

uning

RPN MSB = 00H

RPN LSB = 02H

Data Entry MSB = mmH

m

m

....

M

aster Coarse T

uning = 28H to 40H to 58H (-24 to 0 to

+24 semitones)

Recognition

The data entry LSB is always ignor

ed.

RPN Null

RPN MSB = 7FH

RPN LSB = 7FH

Recognition

Once an RPN Null is sent, all r

eceived data entry MSBs and LSBs

are ignor

ed until another RPN message other than RPN Null or

an NRPN message is r

eceived.

Program Change

Format

Recognition

The value llH mmH is 00H 00H at the lowest pitch, 00H 40H

at mid-pitch, and 7FH 7FH at the highest pitch.

Y

ou have to set both the LSB and MSB together to form a 14-

bit value and make a Pitch Bend Change message r

ecognized

by the instr

ument.