beautypg.com

Troubleshooting guide, Warning – Craftsman 137.21239 User Manual

Page 42

background image

42

To avoid injury from accidental starting, always turn switch OFF and unplug
the tool before moving, replacing the blade or making adjustments.

TROUBLESHOOTING GUIDE - MOTOR

PROBLEM

PROBLEM CAUSE

SUGGESTED CORRECTIVE

ACTION

Brake does
not stop blade
within 10
seconds.

1. Motor brushes not sealed

or lightly sticking.

2. Motor brake overheated

from use of defective or
wrong size blade or rapid
ON/OFF cycling.

3. Arbor bolt loose.
4. Brushes cracked,

damaged, etc.

5. Other.

1. Inspect/clean/replace brushes.

See MAINTENANCE section.

2. Use a recommended blade. Let

cool down. See REMOVING
OR INSTALLING THE BLADE
section.

3. Retighten. See REMOVING

OR INSTALLING THE BLADE
section.

4. Replace brushes.
5. Contact Sears Service Center.

Motor does
not start

1. Limit switch failure
2. Brush worn.
3. Fuse blown or circuit

breaker tripped on home
panel.

1. Replace limit switch.
2. Replace brushes. See

MAINTENANCE section.

3. Verify there is electrical power at

the outlet.

Brush spark
when switch
released.

1. Brush worn.
2. Other.

1. Replace Brushes. See

MAINTENANCE section.

2. Contact Sears Service Center.

WARNING

!