AIR CONDITIONER FEATURES
Before you begin, thoroughly familiarize yourself with the control panel and remote control and all its
functions, then follow the symbol for the functions you desire.
The unit can be controlled by the unit control panel alone or with the remote control.
ELECTRONIC CONTROL OPERATING INSTRUCTIONS
NOTE: This manual does not include Remote Control Operations, see the Remote Control
Instructions packed with the unit for details.
OPERATION PANEL OF THE AIR CONDITIONER
MODE select button
Selects the appropriate operating mode. Each
time you press the button, a mode is selected
in a sequence that goes from AUTO, COOL,
DRY, and FAN.The mode indicator light
illuminates under the different mode setting.
TIMER button
Used to initiate the AUTO ON start time and
AUTO OFF stop time program, in conjuction
with the & buttons.
POWER button
Power switch on/off.
SLEEP button
Used to initiate the SLEEP operation.
FAN button
Control the fan speed. Press to select the fan
speed in four steps - LOW, MED, HI and AUTO.
The fan speed indicator light illuminates under
different fan settings except AUTO speed.
When AUTO fan speed is selected, all of the
fan indicator lights turn dark.
FOLLOW ME indicator
When the FOLLOW ME feature is activated,
the indicator light flashes. This feature can be
activated from the remote control ONLY. See
next page for instructions on using this feature.
UP () and DOWN () buttons
Used to adjust (increase/decrease) temperature
settings (2°F/1°C increments) in a range of 62°F
(17°C) to 88°F (30°C) or the TIMER setting in a
range of 0-24 hrs.
NOTE: The control is capable of
displaying temperature in degrees Fahrenheit or
degrees Celsius. To convert from one to the other,
press and hold the Up and Down buttons at the
same time for 3 seconds.
LED Display
Shows the set temperature in "
O
C" or "
O
F" and
the Auto-timer settings. While on DRY and FAN
modes, it shows the room temperature.
Fig. 4
5
E1- Room temperature sensor error-
Unplug the unit and plug it back in.
If error repeats, call customer service.
E2- Evaporator temperature sensor error-
Unplug the unit and plug it back in.
If error repeats, call customer service.
E4- Display panel communication error-
Unplug the unit and plug it back in.
If error repeats, call customer service.
P1- Bottom tray is full - Connect the drain
hose and drain the collected water away.
If error repeats, call customer service.
Error and protection codes:
NOTE: When more than one error occurs,
the priority of the code display order is:
E4--E2--E1--P1.