Fig.12
Water hose
Female threaded
end
Fig.10
Plastic cover
Drain hose
Adaptor A
Fig.9
Fig.11
Connector
Drain hose
8
OPTION 2: Continuous Draining
Water can be automatically emptied into a floor drain by attaching
a water hose (Inner Diamater ≥ 5/16”, not included) with a female
threaded end (Inner Diameter: M-1”, not included) to the unit
using adaptor A (included) and the short drain hose (included).
● Install the drain hose onto the adaptor A. (See Fig. 9. Adaptor
and drain hose can be found inside the bucket.)
● Remove the plastic cover from the back drain outlet of the unit,
set it aside and remove the bucket. (Take care not to lose the
plastic cover as it is required should you later choose an
alternate drainage option.) Insert the drain hose through the
drain outlet of the unit and securely press it onto the connector
on the front of the unit. (See Fig. 10 and Fig. 11.)
● Tighten adaptor A onto the unit by using the two screws
included with the unit. These screws can be found in a
sectioned off corner of the packaging for this user manual.
● Install the female threaded end of the water hose onto adaptor
A. (See Fig. 12.) Then, lead the water hose to the floor drain or
a suitable drainage facility.
● Make sure the hose is secure so there are no leaks.
● Direct the hose toward the drain, making sure that there are no
kinks that will stop the water from flowing.
● Place the end of the hose into the drain. The hose must be on
a decline so gravity can take the water downward into the
drain. Make sure the end of the hose is level or downward to
the drain, never attempting to push water upwards.
● Plack the bucket back in the unit, making sure it is securely in
the proper place.
● Select the desired humidity setting and fan speed on the unit
for continuous draining to start. (You may choose to run the
unit on Continuous mode so it runs all the time. In Continuous
mode, you will not be able to set a desired humidity setting.)
NOTES:
● When the continuous draining feature is not being used,
remove the drain hose, Adaptor A and short hose from the
continuous drain outlet and place the plastic cover back on the
outlet. Failing to place the plastic cover into the outlet can
cause leaking from the unit.
● A maximum hose length of 6 ft is recommended.
● If you wish to continuously drain through a clear tube (no
threaded end) rather than using the short hose and Adaptor A
to connect to a threaded hose, you can connect a clear tube
(1/2” inner diameter, 5/8” outer diameter, max length of 6 ft)
directly to the connector inside the unit as shown in Fig. 11.
● Continuous mode is different than continous draining.
Continuous mode means the unit will run all the time and you
cannot set a desired humidity. Continuous draining means
that you are choosing to drain water downward into a drain.
You do not have to have the unit on Continuous mode to
use continuous draining.
OPERATING INSTRUCTIONS (CONTINUED)
Adaptor A with