Operating instructions (continued) – Perfect Aire PMP50 User Manual
Page 8

REMOVING THE COLLECTED WATER
There are three ways to remove collected water:
● Use the bucket.
● Continuous draining - gravity takes water down hose into drain.
● Pump Draining - bucket fills, then pump drains water vertically, up to 16 ft.
OPTION 1: Use the bucket
● If the unit is off and the bucket is full, the “Full” indicator light
will illuminate.
● If the unit is on and the bucket is full, the compressor and the fan will
turn off, the “Full” indicator light will illuminate, and the digital display will
show P2.
● Slowly pull out the bucket. Grip the left and right handles securely and
carefully pull out straight so water does not spill. Do not put the bucket
on the floor as the bottom of the bucket is uneven; doing so will cause
the bucket to fall over and water to spill.
● Throw away the water and replace the bucket. The bucket must be
secure and in the correct place for the dehumidifier to operate.
● The machine will re-start when the bucket is restored in its correct
position and the unit is powered on.
NOTES:
● When you remove the bucket, do not touch any parts inside of the unit.
Doing so may damage the product.
● Be sure to push the bucket gently all the way into the unit. Banging the
bucket against anything or failing to push it in securely may cause the
unit not to operate.
● If the pump hose drops when you remove the bucket (see Fig. 7), you
must reinstall the pump hose properly in the unit before replacing the
bucket in the unit (see Fig. 8).
● If there is any water in the unit when you remove the bucket, be sure to
dry it.
● If the bucket is removed when the unit is on, the compressor and the
fan will turn off, the unit will beep 8 times, and the digital display will
show Eb.
● If the bucket is removed when the unit is off, the unit will beep 8 times
and the digital display will show Eb.
1. Pull out the bucket slightly.
2. Hold both sides of the bucket
with even strength and pull it
out from the unit.
3. Pour the water out.
Fig.5
Fig.6
Fig. 7
Pump hose
drops
Fig. 8
Reinstall pump
hose properly
OPERATING INSTRUCTIONS (CONTINUED)
7