DEHUMIDIFIER FEATURES (CONTINUED)
OTHER FEATURES
Bucket Full Light
Illuminates when the bucket is ready to be emptied.
Automatic Shut Off
The dehumidifier shuts off when the bucket is full,
removed, or not placed in the proper position. When
the desired humidity setting is reached, the unit will
cycle off automatically. For some models, the fan
motor will continue operating.
Automatic Defrost
When frost builds up on the evaporator coils, the
compressor will cycle off and the fan will continue to
run until the frost disappears.
Wait 3 Minutes Before Resuming Operation
After the unit has stopped, it cannot begin operating
again for 3 minutes. This is to protect the unit.
Operation will automatically resume after 3 minutes.
Check Filter Feature
The check filter light will automatically flash (once per
second) when the accumulated operation time
reaches 250 hours of operation or more. The system
starts to count the operation time once the fan motor
operates. After you finish cleaning the air filter, press
the Filter pad; the Filter indicator light clears.
Automatic Restart
If the unit breaks off unexpectedly as the result of
having the power cut, it will automatically restart with
the previous function setting when the power resumes.
Setting the Timer
If setting the timer when the unit is on:
First press the TIMER button; the TIMER OFF
indicator light illuminates. It indicates the Auto Stop
program is initiated. Press the TIMER button again;
the TIMER ON indicator light illuminates. It
indicates the Auto Start program is initiated.
If setting the timer when the unit is off:
First press the TIMER button; the TIMER ON
indicator light illuminates. It indicates the Auto Start
program is initiated. Press the TIMER button again;
the TIMER OFF indicator light illuminates. It
indicates the Auto Stop program is initiated.
- Press or hold the UP or DOWN button to change the
Auto time by 0.5 hour increments, up to 10 hours
then at 1 hour increments up to 24 hours. The
control will count down the time remaining until start.
- The selected time will register in 5 seconds and
the system will automatically revert back to
displaying the previous temperature setting.
- When the start and stop times are set within the
same program sequence, the TIMER ON and OFF
indicator lights both illuminate, identifying both ON
and OFF times are now programmed.
- Turning the unit ON or OFF at any time or
adjusting the timer setting to 0.0 will cancel the
Auto Start/Stop timed program.
- When the LED display window shows the code
P2, the Automatic Start/Stop function will also
be canceled.
ERROR AND PROTECTION CODES:
AS - Humidity Sensor Error - Unplug the unit and plug
it back in. If error repeats, call customer service.
ES - Temperature Sensor Error - Unplug the unit
and plug it back in. If error repeats, call
customer service.
P2 - Bucket is Full - Empty the bucket.
Eb - Bucket is removed or not in correct position -
Replace the bucket in the proper position.
EC - Unit Malfunction - Please make sure the
temperature of the environment is suitable for
the proper operation of the unit. The unit should
be operated in an environment from 41ºF (5ºC)
– 95ºF (35ºC). If the unit’s location falls in this
temperature range and you continue to get the
EC error code, call customer service.
E3 - Unit malfunction - Unplug the unit and plug it
back in. If error repeats, call customer service.