Filter replacement and sanitizing procedure – Culligan H-30 User Manual
Page 12
Filter Replacement and Sanitizing Procedure
Use the following procedure and reference in Fig. 1, 4 & 5 when servicing
the Good Water Machine
™
.
NOTICE:
You may want to fill a pitcher with drinking water before beginning
service as it will take several hours for the system to refill after servicing.
The Good Water Machine may be sanitized with either 5-1/4% liquid chlorine
bleach or a fresh bottle of consumer grade hydrogen peroxide.
NOTICE:
The reverse osmosis membrane filter used in this system may be
severely damaged by chlorine. The membrane filter must be removed from
the system if chlorine bleach is to be used for sanitizing.
NOTICE:
Hydrogen peroxide should not be used if iron is present in the
supply water as the RO membrane filter may be damaged.
Cleanliness is essential in the filter replacement procedure. Be sure to wash
your hands thoroughly before handling filters. The use of surgical gloves is
strongly recommended.
9
Fig. 4
Fig. 5