Operation – CMA Dishmachines CMA-180UC User Manual
Page 18

Operation
PROBLEM LIKELY
CAUSE
SOLUTION
Start switch requires > 1
second activation to run
cycle
Defective (Instant Start) ice cube
relay
Replace ice cube relay
P/N: 00631.00
Defective drain/fill switch
Replace drain/fill switch
P/N: 15522.00
Activating fill switch does
not fill machine
Defective water solenoid valve
Replace water solenoid valve
P/N: 03603.10
Defective water solenoid valve
Replace water solenoid valve
P/N: 03603.10
Defective drain/fill switch
Replace drain/fill switch
P/N: 15522.00
Defective timer assembly
Replace timer assembly*
P/N: 14408.80
Fill (rinse water) won’t shut
off
Defective (Rinse Relay) ice cube
relay
Replace ice cube relay
P/N: 00631.00
Drain hose is kinked
Un-kink drain hose
Defective drain/fill switch
Replace drain/fill switch
P/N: 15522.00
Activating drain switch
does not drain machine
Defective drain valve
Replace drain valve
P/N: 04103.00
Cycle light does not light
while cycle runs
Defective cycle light
Replace cycle light (green)
P/N: 00406.60
Power light does not light
but machine runs
Defective power light
Replace power light (red)
P/N: 00406.00
Wash tank or final rinse
temperature does not
display
Defective digital thermometer
Replace digital thermometer
P/N: 03202.45
Both the wash tank
temperature and the final
rinse temperature do not
display
Defective thermometer
transformer
Replace thermometer
transformer
P/N: 03202.60
Defective digital thermometer
Replace digital thermometer
P/N: 03202.45
Wash tank or final rinse
displays wrong
temperature
Defective thermister
Replace thermister
P/N: 03202.65
*The timer assembly motor (
P/N: 00501.00
) or micro switches (
P/N: 00411.00
) can be replaced
independently if that’s the only component that’s failed.
MODEL CMA-180UC INSTALLATION & OPERATION MANUAL Rev. 1.13
Page
17