Operation
3.6. Troubleshooting
PROBLEM LIKELY
CAUSE
SOLUTION
Power off at circuit breaker
Reset circuit breaker
Machine inoperative
Defective power switch
Replace power switch
P/N: 15521.50
Door is open
Close door
Control panel is pulled out
Secure control panel
Defective reed switch
Replace reed switch
P/N: 00557.55
Defective timer assembly
Replace timer assembly*
P/N: 14408.80
Defective pump motor contactor
Replace contactor
P/N: 15504.00
Motor inoperative
Defective motor
Replace motor
P/N: 00201.66
Defective reed switch
Replace reed switch
P/N: 00557.55
Motor runs with door open
Defective pump motor contactor
Replace contactor
P/N: 15504.00
High limit switch opened or
defective
Reset or replace switch
P/N: 17523.51
Defective thermostat
Replace thermostat
P/N: 13417.89
Defective heater contactor
Replace heater contactor
P/N: 15504.50
Heater (no heat)
Defective heater
Replace heater
P/N: 15517.00
Defective thermostat
Replace thermostat
P/N: 13417.89
Heater (never turns off)
Defective heater contactor
Replace heater contactor
P/N: 15504.50
*The timer assembly motor (
P/N: 00501.00
) or micro switches (
P/N: 00411.00
) can be replaced
independently if that’s the only component that’s failed.